Cause:
Excessive bushing and shaft clearance caused by normal wear.
Correction:
The Sonnax bushing allows salvage of the pump by oversizing the housing bore for installation of a new, tightly toleranced bushing
Normal operation of the ZF5HP19 transmission causes wear that leads to excessive bushing and shaft clearance. Sonnax oversized pump bushings 95410 and 95412 contain one pump bushing each to allow rebuilders to salvage pumps with damaged bushing bores.
Oversized precision bushing 95410 allows rebuilders to salvage costly pumps with damaged bushing bores
Oversized finish-in-place bushing 95412 allows rebuilder to salvage pumps with damaged bushing bores, and set clearance with converter hub
Tightly toleranced, bimetal
Note:
Bushings are oversized precision bushings for damaged pump housings. The pump-housing bushing-bore ID will require machining. Bore pump housing to 2.0020” (50.85mm) plus zero/minus .0015” (0.040mm). Outside of pump and front seal bore are both concentric to original pump bushing bore so either can used for centering pump prior to machining. Original housing bore is 1.0693" (50.020mm).
Symptoms:
Cause: Excessive bushing and shaft clearance caused by normal wear.
Correction: The Sonnax bushing allows salvage of the pump by oversizing the housing bore for installation of a new, tightly toleranced bushing
Normal operation of the ZF5HP19 transmission causes wear that leads to excessive bushing and shaft clearance. Sonnax oversized pump bushings 95410 and 95412 contain one pump bushing each to allow rebuilders to salvage pumps with damaged bushing bores.
Note: Bushings are oversized precision bushings for damaged pump housings. The pump-housing bushing-bore ID will require machining. Bore pump housing to 2.0020” (50.85mm) plus zero/minus .0015” (0.040mm). Outside of pump and front seal bore are both concentric to original pump bushing bore so either can used for centering pump prior to machining. Original housing bore is 1.0693" (50.020mm).
Specifications:
SONNAX Installation Instructions